Test Code TYSC Type and Screen

Additional Codes

Hospital Ordering Code

Lab276   Type and Screen 

Specimen Requirements

Specimen Type: Whole blood

Container/Tube: Lavender top (EDTA) or plain, red top

Specimen Volume: 7 mL

Collection Instructions:

1. Invert several times to mix blood.

2. Specimen >2 days old or plasma or serum gel tube is not acceptable.

Additional Information:

1. Patient must be wearing an identification bracelet.

2. All specimens must be completely labeled in accordance with AABB requirements.

Performing Laboratory

Unity Point-Sioux City-Blood Bank

CPT

86900-ABO

86901-Rh

86850-AB Screen

Specimen Transport Temperature

Refrigerate 2 days

Day(s) Test Set Up