Test Code SCLA Anti-Scleroderma Antibody
Additional Codes
Hospital Ordering Code |
LAB771 Anti-scleroderma antibody |
Specimen Requirements
Preferred Collection Container:
Red (No Additive)
SST (Serum Separator)
Collection Information:
Collect 1.0 mL of blood. Transfer 0.5 mL of serum to a transport vial.
Minimum Sample Volume:
0.25 mL
Unacceptable Conditions:
Grossly hemolyzed or lipemic specimens.
Stability Comments:
Plasma samples from green and lavender top tubes are acceptable, but will route to a PROBL spot in the Sunquest Laboratory Information System.
Specimen Transport Temperature
Refrigerated Stability:
7 days
Frozen Stability:
Indefinitely
Performing Laboratory
Pathology Laboratory, UnityPoint Health, Des Moines
CPT
86235
Methodology
Multiplex Flow Immunoassay
Day(s) Test Set Up
Performed:
Monday through Friday
Analytical Time:
1 day