Sign in →

Test Code RENAL Renal Function Panel

Additional Codes

Epic EAP
LAB19  RENAL FUNCTION PANEL
LAB0019 (RENALF) RENAL FUNCTION PANEL - FASTING 

Specimen Requirements

Submit only 1 of the following specimens:

 

Specimen Type: Plasma

Container/Tube: Green top (lithium heparin)

Specimen Volume: 0.5 mL

Collection Instructions: Hemolyzed specimen is not acceptable.

Additional Information: Label specimen appropriately (plasma).

 

Specimen Type: Serum

Container/Tube: Serum gel

Specimen Volume: 0.5 mL

Collection Instructions: Hemolyzed specimen is not acceptable.

Additional Information: Label specimen appropriately (serum).

Performing Laboratory

Unity Point-Sioux City-Chemistry

CPT

80069

Methodology

Profile Information:
BUN/Creatinine Ratio Glucose
Calcium Potassium
Carbon Dioxide (CO2) Sodium
Chloride Urea Nitrogen (BUN)
Creatinine Alb
Phos  

 

Day(s) Test Set Up

Monday through Sunday

Specimen Transport Temperature

Ambient

Calculation

Estimated glomerular filtration rate equation:

 

 

Male

 

If CREA/0.9 >1 

(((142*1)*((CREA/0.9)^-1.2))*(0.9938^age in yrs))

 

If CREA/0.9 <1

(((142*((crea/0.9)^-0.302))*(0.9938^age in yrs))

 

 

Female

 

If CREA/0.7 >1

(((142*((CREA/0.7)^-1.2))*(0.9938^age in yrs))*1.012)

 

If CREA/0.7 <1

(((142*((crea/0.7)^-0.241))*(0.9938^age in yrs))*1.012)