Sign in →

Test Code MISLAB; HEP A PCR Hepatitis A Virus (HAV), PCR

Additional Codes

Epic EAP
LAB2608; Hepatitis A Virus (HAV), PCR 

Specimen Requirements

Preferred Collection Container: 

SST (Serum Separator)

 

Also Acceptable Collection Container: 

Red (No Additive)

 

Collection Information: 

Collect blood in a SST (Serum Separator). Red (No Additive) also acceptable.

 

Transport Information: 

Centrifuge and aliquot 1.0 mL of serum into a plastic transport vial. Send refrigerated.

 

Minimum Sample Volume: 

1.0 mL of serum (approximately 2.0 mL of whole blood based upon a normal patient hematocrit)

 

Unacceptable Conditions: 

Plasma, CSF. Contaminated, heat-inactivated, hemolyzed, or severely lipemic specimens. Specimens not received in the correct temperature ranges stated under "Temperature and Stability" will be rejected.

Stability

Refrigerated Stability: 

14 days

Performing Laboratory

State Hygienic Laboratory-Coralville

Methodology

Nucleic Acid Amplification by Real-Time Polymerase Chain Reaction (PCR)

CPT

87798

Performed

Prior approval by an Iowa Health and Human Services epidemiologist must be obtained.
Contact Iowa HHS CADE at (515) 242-5935 (business hours) or (515) 323-4360 (non-business hours) for form.

 

Analytical Time: 

1 - 2 days

 

Testing Laboratory: 

State Hygienic Laboratory at the University of Iowa; Coralville, IA