Test Code MISLAB / 45510E Caraway Seed (Carum carvi) IgE
Additional Codes
| Epic EAP | Sunquest Ordering Code |
|---|---|
| LAB2608 | MISLAB; 45510e Caraway Seed (Carum carvi) IgE |
Specimen Requirements
Collect 1-2 mL whole blood in red top tube.
Centrifuge and transfer 0.5 mL serum into a transfer tube.
Lipemic samples may lead to rejection.
Stability
Ship at ambient or frozen temperature Monday through Friday.
Ambient Stability:
4 weeks
Refrigerated Stability:
4 weeks
Frozen Stability:
More than1 month
Performing Laboratory
Viracor Eurofins Clinical Diagnostics
Performed
Monday - Friday
1-2 business days from receipt of specimen
Methodology
The ImmunoCAP® FEIA method uses as the solid phase a flexible, hydrophobic cellulosic polymer to which allergen has been covalently linked. The advantage of this system is that it has a very high antigen binding capacity when compared to other systems and it has minimal non-specific binding with high total IgE. Eurofins Viracor provides an optional low range calibrator at 0.1 kU/L and a 0/1 class. This test has not been cleared or approved for diagnostic use by the U.S. Food and Drug Administration.
CPT
86003