Sign in →

Test Code ESTGM Estrogens, Estrone (E1) and Estradiol (E2), Fractionated, Serum

Additional Codes

EPIC EAP  Mayo
LAB980 ESTF

 

Reporting Name

Estrogens, E1+E2, fractionated, S

Useful For

Simultaneous high-sensitivity determination of serum estrone and estradiol levels

 

Situations requiring either higher sensitivity estradiol measurement, estrone measurement, or both, including

-As part of the diagnosis and workup of precocious and delayed puberty in females and, to a lesser degree, males

-As part of the diagnosis and workup of suspected disorders of sex steroid metabolism, (eg, aromatase deficiency and 17 alpha-hydroxylase deficiency)

-As an adjunct to clinical assessment, imaging studies, and bone mineral density measurement in the fracture risk assessment of postmenopausal women and, to a lesser degree, older men

-Monitoring low-dose female hormone replacement therapy in postmenopausal women

-Monitoring antiestrogen therapy (eg, aromatase inhibitor therapy)

 

Applications that require moderately sensitive measurement of estradiol including:

-Evaluation of hypogonadism and oligo-amenorrhea in females

-Assessing ovarian status, including follicle development, for assisted reproduction protocols (eg, in vitro fertilization)

 

In conjunction with luteinizing hormone measurements, monitoring of estrogen replacement therapy in hypogonadal premenopausal women

 

Evaluation of feminization, including gynecomastia, in males

 

Diagnosis of estrogen-producing neoplasms in males, and, to a lesser degree, females

Profile Information

Test ID Reporting Name Available Separately Always Performed
E1 Estrone, S Yes Yes
EEST Estradiol, Mass Spectrometry, S Yes Yes

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

Serum Red


Specimen Required


Supplies: Sarstedt Aliquot Tube 5 mL (T914)

Collection Container/Tube: Red top (Serum gel/SST is not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 1.2 mL

Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum in plastic vial.


Specimen Minimum Volume

0.7 mL

Specimen Stability Information

Specimen Type Temperature Time
Serum Red Refrigerated (preferred) 28 days
  Ambient  28 days
  Frozen  28 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Special Instructions

Day(s) Performed

Monday through Sunday

CPT Code Information

82671-Estrogens, fractionated

82670-Estradiol (If appropriate)

82679-Estrone (If appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
ESTF Estrogens, E1+E2, fractionated, S 53766-2

 

Result ID Test Result Name Result LOINC Value
81418 Estrone, S 2258-2
81816 Estradiol, Mass Spectrometry, S 2243-4

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

Report Available

2 to 6 days

Forms

If not ordering electronically, complete, print, and send General Test Request (T239) with the specimen.