Test Code CEYE Culture, Eye, with Gram Stain
Additional Codes
| Epic EAP |
|---|
| LAB943 Eye culture |
Specimen Requirements
Container/Tube Type:
Copan ESwab
Sterile Container
Collection Information:
Collect using a Copan ESwab for superficial collections or for drainage or aspirated samples place in a sterile container
Remarks:
Identification and susceptibility tests are billed separately from culture.
Stability
Ambient Stability:
24 hours
Performing Laboratory
Pathology Laboratory, UnityPoint Health, Des Moines
CPT
87070 - Culture
87205 - Gram stain
Methodology
Organism Identification is performed by biochemical test and/or Bruker MALDI-TOF mass spectrometry RUO Database. Organism sensitivities (AST) are performed as applicable using Broth Microdilution and/or Gradient diffusion strips using FDA approved methodology and CLSI guidelines. Performance has been evaluated and verified by UnityPoint Health - Des Moines, Pathology Laboratory.
Performance
Setup daily, 24 hours a day
Analytical Time:
2 days
Analytical time listed is the average time for a negative culture. Average analytical time may vary for positive, mixed, and complex cultures. Contact the lab for specific questions.
Testing Laboratory:
Pathology Laboratory
Laboratory Section:
Microbiology
Alias
Aerobic Bacteria Culture, Eye, Aerobic Culture