Test Code CEA CEA

Additional Codes

Hospital Ordering Code
LAB57    CEA

Specimen Requirements

Container/Tube Type: 

Green (Lithium Heparin)
Lime Green (Heparin Plasma Separator Tube)
Red (No Additive)
SST (Serum Separator)

 

Preferred Collection Container: 

Green (Lithium Heparin)
Light Green (Heparin Plasma Separator Tube)

 

Also Acceptable Collection Container: 

Plasma from Lavender tubes is acceptable but will not route in the Laboratory Information System (Sunquest).

 

Transport Information: 

3.0 mL blood/1.0 mL serum

 

Minimum Sample Volume: 

0.6 mL blood/0.2 mL serum

 

Remarks: 

CEA assay testing is not recommended as a screening procedure to diagnose cancer in the general population.

Specimen Transport Temperature

Refrigerated Stability: 

7 days

 

Frozen Stability: 

6 months

Performing Laboratory

Pathology Laboratory, UnityPoint Health, Des Moines

CPT

82378

Methodology

Electrochemiluminescence

 

Interpretive Data: 

The testing method is an electrochemiluminescence assay manufactured by Roche Diagnostics Inc. and performed on the Cobas system. Values obtained with different assay methods or kits may be different and cannot be used interchangeably.

Day(s) Test Set Up

Monday-Friday 8:00a to 10:00p
Saturday-Sunday 9:00a to 5:00p

 

Analytical Time: 

4 hours

Alias

CEA, Serum, Embryonic Carcinoma Antigen, Carcinoembryonic Antigen (CEA)