Test Code CBLAFB Culture, Acid Fast, Blood
Additional Codes
Epic EAP |
---|
LAB246 Culture Blood Acid Fast |
Specimen Requirements
Container/Tube Type:
BD Bactec Myco/F Lytic Culture Vial
Collection Information:
Contact laboratory prior to collection for BD Bactec Myco/F Lytic Culture Vial. Disinfect the top of the tube stopper with 70% isopropyl alcohol wipe prior to collection.
Patient preparation: Clean venipuncture site with Chloraprep swab for 15 seconds. Allow to dry for 30 seconds. The site must be dry before performing the venipuncture. Do not touch the site with any non-sterile object.
Collection Volume:
Optimal Volume: 3.0 mL - 5.0 mL
* Collecting the optimal volume significantly increases the recovery rate
Minimum Sample Volume:
Minimum difficult adult draw and pediatric: 1.0 mL
Unacceptable Conditions:
Clotted, improper container or Does not meet collection, storage or transport requirements. No more than 3 blood cultures will be accepted per patient per 24-hour period unless authorized by Microbiology Manager, Pathologist, or Director of Laboratory Services
Specimen Transport Temperature
Refrigerated Stability:
24 hours
Frozen Stability:
NOT Acceptable
Ambient Stability:
24 hours
Performing Laboratory
Pathology Laboratory, UnityPoint Health, Des Moines
CPT
87116
87206
87015
Methodology
BD Bactec Myco/F Lytic Culture Vial/ ESP Continuous Monitoring System
Performance
Setup daily, 24 hours a day. (Cultures read on the dayshift only.)
Analytical Time:
Smear results 24 hours, Culture 8 weeks