Test Code BCRBAT BCR/ABL1, p210, mRNA Detection, Reverse Transcription-PCR (RT-PCR), Quantitative, Monitoring Chronic Myeloid Leukemia (CML), Blood
Additional Codes
| Epic EAP |
|---|
| LAB2842 BCR/ABL P210 QUANTITATIVE MONITOR |
Specimen Requirements
Preferred Collection Container:
Lavender (EDTA) - Collect Two (2) Tubes
Also Acceptable Collection Container:
Pink (K2EDTA)
Collection Information:
Collect blood in a lavender (EDTA) tube. Pink (K2EDTA) also acceptable. Note: Two (2) Lavender (EDTA) tubes need to be collected to get 4.0 mL of EDTA blood for testing.
Transport Information:
Send 4.0 mL of whole blood in original tube, refrigerated. Do not centrifuge or aliquot.
Minimum Sample Volume:
4.0 mL of EDTA whole blood
Unacceptable Conditions:
Frozen samples, serum samples
Stability
Refrigerated Stability:
72 hours - Preferred
Frozen Stability:
Not Acceptable
Ambient Stability:
Not Acceptable
Performing Laboratory
Pathology Laboratory, UnityPoint Health, Des Moines
CPT
81206
Performance
Monday through Friday, Day shift only
Analytical Time:
4 hours
Testing Laboratory:
Pathology Laboratory
Laboratory Section:
Microbiology
Methodology
Real-time Reverse Transcription Polymerase Chain Reaction (RTqPCR)