Sign in →

Test Code A1ATM SERPINA1 Gene, Full Gene Analysis, Varies

Additional Codes

Hospital Order Code
Lab2608   MISMGO


Shipping Instructions


 



Necessary Information


 



Specimen Required


Patient Preparation: A previous hematopoietic stem cell transplant from an allogenic donor will interfere with testing. For information about testing patients who have received a hematopoietic stem cell transplant, call 800-533-1710.

 

Submit only 1 of the following specimens:

 

Specimen Type: Whole blood

Container/Tube: Lavender top (EDTA) or yellow top (ACD)

Specimen Volume: 3 mL

Collection Instructions:

1. Invert several times to mix blood.

2. Send whole blood specimen in original tube. Do not aliquot.

3. Whole blood collected postnatal from an umbilical cord is also acceptable. See Additional Information

Specimen Stability Information: Ambient (preferred) 4 days /Refrigerated 4 days/Frozen 4 days

Additional Information:

1. Specimens are preferred to be received within 4 days of collection. Extraction will be attempted for specimens received after 4 days, and DNA yield will be evaluated to determine if testing may proceed.

2. To ensure minimum volume and concentration of DNA are met, the requested volume must be submitted. Testing may be canceled if DNA requirements are inadequate.

3. For postnatal umbilical cord whole blood specimens, maternal cell contamination studies are recommended to ensure test results reflect that of the patient tested. A maternal blood specimen is required to complete maternal cell contamination studies. Order MATCC / Maternal Cell Contamination, Molecular Analysis, Varies on both the cord blood and maternal blood specimens under separate order numbers.

 

Specimen Type: Extracted DNA

Container/Tube:

Preferred: Screw Cap Micro Tube, 2 mL with skirted conical base

Acceptable: Matrix tube, 1 mL

Collection Instructions:

1. The preferred volume is at least 100 mcL at a concentration of 75 ng/mcL.

2. Include concentration and volume on tube.

Specimen Stability Information: Frozen (preferred) 1 year/Ambient/Refrigerated

Additional Information: DNA must be extracted in a CLIA-certified laboratory or equivalent and must be extracted from a specimen type listed as acceptable for this test (including applicable anticoagulants). Our laboratory has experience with Chemagic, Puregene, Autopure, MagnaPure, and EZ1 extraction platforms and cannot guarantee that all extraction methods are compatible with this test. If testing fails, one repeat will be attempted, and if unsuccessful, the test will be reported as failed and a charge will be applied. If applicable, specific gene regions that were unable to be interrogated due to DNA quality will be noted in the report.


Forms

1. New York Clients-Informed consent is required. Document on the request form or electronic order that a copy is on file. The following documents are available:

-Informed Consent for Genetic Testing (T576)

-Informed Consent for Genetic Testing-Spanish (T826)

2. Molecular Genetics: SERPINA1 Gene Patient Information (T521)

3. If not ordering electronically, complete, print, and send a Gastroenterology and Hepatology Test Request (T728) with the specimen.

Useful For

Identification of causative variants when a deficient serum level of alpha-1-antitrypsin is not explained by routine testing, such as proteotyping, genotyping, or isoelectric focusing phenotyping

 

Determining the specific allelic variant (full gene analysis) for prognosis and genetic counseling

Testing Algorithm

For cord blood specimens that have an accompanying maternal blood specimen, maternal cell contamination studies will be performed at an additional charge.

 

For more information see Alpha-1 Antitrypsin-A Comprehensive Testing Algorithm.

Method Name

Polymerase Chain Reaction (PCR) Amplification/DNA Sequencing

Reporting Name

SERPINA1 Gene, Full Gene Analysis

Specimen Type

Varies

Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time
Varies Varies

Reject Due To

  All specimens will be evaluated by Mayo Clinic Laboratories for test suitability.

Reference Values

An interpretive report will be provided.

Day(s) Performed

Varies

Report Available

14 to 20 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

81479

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SERPZ SERPINA1 Gene, Full Gene Analysis 94222-7

 

Result ID Test Result Name Result LOINC Value
113178 Result Summary 50397-9
113179 Result 82939-0
113180 Interpretation 69047-9
113181 Additional Information 48767-8
113182 Specimen 31208-2
113183 Source 31208-2
113184 Released By 18771-6

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
MATCC Maternal Cell Contamination, B Yes No